R-SP-E12 Surge Protection Module
The R-SP-E12 is a device designed to protect fieldbus network segments in hazardous areas
HS CODE : 8428909090
Product No :
R-SP-E12Manufacture :
Pepperl FuchsSize (cm) :
11.4*1.25*9.9Weight (kg) :
0.08Origin :
SingaporeWarranty :
12 MonthLead Time :
Ready StockDescription :
Processor UnitProduct parameters
Power supply: Field bus connection 9... 32 V DC, the maximum main line is 32 V / 40 mA, the maximum rated voltage of the branch is 32 V, the maximum rated current is 52 mA, and the short-circuit current refers to the general instructions.
Interface (Field Bus) : Trunk: Fixed screw terminals, supporting shielding and grounding concepts; Spur: 12 Ex e outputs, maximum spur length depends on cable type (e.g., 1m under 0.8mm ² cable), short-circuit protection limits current.
Performance indicators: Supports up to 31 devices/segments, with a maximum cable length of 1900 m (depending on the cable type), integrated terminal resistance of 100 Ω (optional), surge protection for both main and branch lines, and an automatic response time to recover from a fault of less than 1 second.
Isolation and Security The main and branch circuits are Ex e (enhanced safety), the section protectors are installed in Zone 1/ Div.2, the instruments are installed in Zone 1/ Div.1, the protection grade is IP20 (inside the cabinet), it complies with SIL 2/3 (IEC 61508), and the electromagnetic compatibility complies with EN 61326-1:2013.
Certification: CE, ATEX (II 2G Ex e IIC T4 Gb, etc.), IECEx, cULus, compliant with 2014/34/EU (Equipment Directive) and EN 60079 series, applicable to hazardous areas.
Mechanical parameters: Dimensions approximately 20 x 124 x 115 mm (DIN rail module), weight approximately 200 g, installed on 35 mm DIN rail, fixed screw terminal (2.5 mm² / AWG 12-24), ambient temperature -40... 70 °C, humidity 5... 95% (non-condensing), spring terminals are optional.
Function
As a device coupler connecting field instruments to the bus segment, it provides short-circuit protection for 12 branches. In case of a fault, it automatically limits the current to ensure the overall operation of the segment.
Integrated surge protection and an optional 100 Ω terminal resistor, supporting high availability design and thermal operation maintenance (permission required).
It is equipped with LED indicator lights to display power, faults and section status, which is convenient for diagnosis and maintenance, and automatically restores the function of the branch circuit.
Supports the High-Power Trunk concept, is compatible with Entity and FISCO models, and allows for mixed instrument topologies and redundant power supplies.
Easy to integrate inside the cabinet, supports custom enclosures, is compatible with FOUNDATION Fieldbus and PROFIBUS PA, and provides advanced diagnostic modules.
Application scenarios
R-SP-E12 is widely used in process industries such as petrochemicals, pharmaceuticals, oil refining and mining, and is suitable for cabinet installation in Zone 1/ Div.2 and field instrumentation in Zone 1/ Div.1. It is used to protect the field bus segment from branch short circuits, ensure segment continuity during thermal operation or equipment maintenance, and support diagnostic applications in IIoT and Industry 4.0. The equipment complies with ATEX, IECEx and cULus certifications and is suitable for automation systems that require high reliability and explosion protection, such as fieldbus infrastructure in large process plants.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
7/24 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies