1408-EM3A-ENT Allen-Bradley PowerMonitor 1000 Energy Monitor EM3
1408-EM3A-ENT is an energy management meter with Ethernet/IP communications manufactured by Allen-Bradley.
HS CODE : 8538909200
Product No :
1408-EM3A-ENT 1408EM3AENTManufacture :
Allen BradleySize (cm) :
5 * 5 * 3Weight (kg) :
0.4Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
ENERGY MONITORElectrical parameters:
Input voltage: Directly connected to a maximum of 600V AC three-phase line-to-line, with a maximum nominal line-to-ground voltage of 347V. For higher voltages, potential transformers (PTs) need to be used.
Power supply: Powered by 120/240V AC power supply.
Current: Rated current 5A (through the current transformer).
Frequency range: 40-75 Hz.
Measurement accuracy: 1% (applicable to voltage, current and power measurement).
Communication interface:
Serial communication: Supports RS-485 communication (DF1 full/half duplex, Modbus RTU).
EtherNet communication: Supports 100BaseT Ethernet (EtherNet/IP and Modbus TCP protocol).
Physical parameters:
Installation method: Panel Mount.
Environmental conditions:
Operating temperature: 0-55°C (typical industrial environment).
Humidity: 5-95%
Function
Comprehensive energy monitoring
Monitor all key energy parameters in real time, including power consumption, demand (actual and predicted), power factor, etc.
Provide detailed power energy data for analyzing and optimizing energy usage.
Communication and Integration
Supports EtherNet/IP and Modbus TCP protocols and can be seamlessly integrated into industrial automation systems (such as Allen-Bradley PLC or SCADA systems).
Compatible with RSLinx Classic or OPC software for data acquisition and remote monitoring.
It is equipped with a built-in Web interface for convenient remote data viewing and device configuration.
Data Recording and Reporting
Supports the generation of reports on energy consumption, demand and power factor, suitable for energy consumption analysis and cost allocation.
Historical data can be recorded for trend analysis and fault diagnosis.
Compact and cost-effective:
Compact design, suitable for installation in control cabinets with limited space.
We offer cost-effective energy monitoring solutions suitable for small and medium-sized industrial applications.
Protection function:
Provide current and voltage imbalance monitoring to help identify potential electrical problems.
Support basic protection functions, such as abnormal power detection.
Application scenarios
Industrial Energy Management
Energy monitoring for manufacturing and production facilities, optimizing electricity usage and reducing operating costs.
Monitor the energy consumption of production lines or equipment, identify high-energy-consuming links and make improvements.
Architecture and Facilities Management
It is applied to the power systems of commercial buildings or factories to monitor the energy consumption of HVAC, lighting or other equipment.
Supports energy audits and cost allocation, suitable for multi-tenant buildings or departmental energy consumption management.
SCADA system integration
Integrated into the SCADA system via EtherNet/IP or Modbus TCP, it is suitable for remote monitoring and data acquisition.
It is commonly seen in water treatment, petrochemicals or other industries that require real-time power data.
Water treatment and public facilities
It is used for energy monitoring in pumping stations or sewage treatment plants to optimize the operational efficiency of pumps and motors.
Support energy management projects in municipal engineering.
Data center: Monitor the energy consumption of servers and cooling systems to ensure efficient operation and reduce electricity costs.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
CC-CGPT01 |
CC-MCAR01 |
CC-TDI220 |
CC-GDIL11 |
CC-MCARW1 |
CC-TDI230 |
CC-HCAR01 |
CC-MCC003 |
CC-TEIM01 |
CC-HCMB02 |
CC-MDUN12 |
CC-TSP411 |
CC-HUIO11 |
CC-MDUR18 |
CC-TSV211 |
CC-HUIO12 |
CC-PDIS01 |
CC-ZC3002 |
CC-KFPVR5 |
CC-PEIM01 |
CC-ZHMT10 |
CC-KFSGR5 |
CC-PFB802 |
CC-ZHR011 |
CC-KFSVR5 |
CC-PSP401 |
CC-ZHR012 |
CC-KREB01 |
CC-PSV201 |
CC-ZHR020 |
CC-KREB02 |
CC-PWN401 |
CC-ZHR021 |
CC-KREB05 |
CC-PWR401 |
CC-ZHR031 |
CC-KREB10 |
CC-PWRB01 |
CU-PWMN20 |
CC-KREB20 |
CC-PWRN01 |
CU-PWMR20 |
CC-KREB30 |
CC-SDXX01 |
CU-PWPR20 |
CC-KREB40 |
CC-TAIL51 |
MC-ZAIHF3 |
CC-KREB50 |
CC-TAON11 |
MC-ZAOXF2 |
CC-KREBR5 |
CC-TDI151 |
MC-ZAOXF3 |
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies