5069-L320ER Allen Bradley Rockwell CompactLogix Controller
5069-L320ER is a CompactLogix 5380 controller.
HS CODE : 8538909200
Product No :
5069-L320ER 5069L320ERManufacture :
Allen BradleySize (cm) :
20 * 19 * 15Weight (kg) :
1Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
ControllerProduct parameters
Controller type: CompactLogix 5380 standard controller (no safety functions, no motion control)
Memory:
User memory: 2 MB
Non-volatile storage: 2GB (standard 1784-SD2 SD card), supports expansion to:
1 GB (1784-SD1)
8 GB (1784-SDHC8)
32 GB (1784-SDHC32)
4 GB (9509-CMSDCD4 CodeMeter CmCard)
Task support:
Maximum number of tasks: 32 (standard tasks)
Number of programs per task: up to 1000
Communication interface:
2 Ethernet /IP ports (supporting 10 Mbps, 100 Mbps, 1 Gbps, full-duplex)
One USB 2.0 port (for programming and configuration, 12 Mbps)
Network support
Maximum Ethernet /IP node: 40
Maximum socket interface: 32
Supported network topologies: Linear, Star, Device-level Loop (DLR)
Ethernet mode: Dual IP mode (independent IP address per port) or linear /DLR mode (shared IP address)
I/O support:
Maximum local I/O modules: 16 (Compatible with Allen-Bradley 5069 Compact I/O modules)
Distributed I/O: Access the Ethernet /IP network via 5069-AEN2TR or 5069-AENTR
I/O capacity: 128,000 data packets per second
Power supply:
Module Power supply (MOD Power) : 18-32 V DC (SELV/PELV), maximum current 475 mA, surge current 850 mA (lasting for 125 ms)
Maximum power supply current: 9.55A (DC)
Sensor/Actuator (SA) power supply:
Voltage range: 0-32 V DC or 0-240 V AC (47-63 Hz, ATEX/IECEx maximum 125 V AC)
Maximum current: 9.975A (AC), 9.95A (DC)
On-site power supply current: 25 mA (AC), 10 mA (DC)
Power consumption:
Maximum power consumption: 8.5 W
Maximum heat dissipation: 29 BTU/hr
Installation:
DIN rail installation (Recommended zinc-chrome-plated steel EN50022 rail, 35 x 7.5mm, only supports horizontal installation)
Grounding requirements: A DIN rail with good electrical conductivity is required to ensure reliable grounding
Environmental conditions:
Operating temperature: 0°C to 60°C (32°F to 140°F)
Storage temperature: -40°C to 85°C (-40°F to 185°F)
Relative humidity: 5% to 95% (no condensation)
Vibration: 5 g (10-500 Hz)
Impact: 30 g during operation (3 pulses, 11 ms), 50 g during non-operation
Enclosure: Open type (needs to be installed in a cabinet with an appropriate protection level, dust-proof and resistant to corrosive gases)
Programming language: Supports IEC-61131-3 standard, including ladder Diagram (LD), Function Block Diagram (FBD), Structured Text (ST), and Sequential Function Diagram (SFC).
Certification:
Comply with EMC standards (EN 50081-2, EN 50082-2)
Type test: 50 V or 300 V isolation voltage (depending on the insulation type)
Function
High-performance task processing
Supports up to 32 standard tasks, with each task capable of containing 1000 programs, making it suitable for complex control logic.
It provides 2 MB of user memory to meet the storage requirements of small and medium-sized automated applications.
Flexible network connection
The dual Ethernet /IP ports support 10/100 Mbps and 1 Gbps full-duplex communication, and support linear, star and DLR topologies, providing network redundancy and fault tolerance.
Supports up to 40 Ethernet /IP nodes and 32 socket interfaces, suitable for distributed control systems.
The USB 2.0 port is used for programming, configuration and debugging, and the communication rate reaches 12 Mbps.
Modular I/O expansion
Supports up to 16 local I/O modules (5069 Compact I/O), and distributed I/O can be expanded through 5069-AEN2TR or 5069-AENTR.
The I/O capacity reaches 128,000 data packets per second, supporting high-throughput data processing.
Programming and Configuration
Programming is carried out using Studio 5000 Logix Designer software (version 31 or higher), supporting ladder diagram (LD), Function Block Diagram (FBD), Structured text (ST), and Sequential Function Diagram (SFC).
Support all event triggering to ensure flexible task scheduling.
Reliability and environmental adaptability:
The open shell design requires installation in a protective cabinet to adapt to industrial environments (dust-proof and resistant to corrosive gases).
Supports DIN rail installation. It is recommended to use zinc-chrome-plated steel rails with good electrical conductivity to ensure grounding reliability.
Withstand vibration (5 g) and shock (30 g during operation and 50 g during non-operation).
Diagnosis and Monitoring
Provide a status indicator to display the operating status of the controller in real time.
It supports fault reporting, module suppression and electronic key functions, facilitating system diagnosis and maintenance.
Application scenarios
Manufacturing Automation
It is used to control production lines, assembly lines and packaging equipment, and handle standard control tasks (such as sensor and actuator management).
Suitable for small and medium-sized factories, it meets the requirements of limited I/O points and moderate complexity control.
Material handling
It is applied to conveyor belts, automated warehousing and sorting systems, supporting high-performance task processing and real-time data transmission.
Dual Ethernet ports and DLR topology ensure network reliability, making it suitable for dynamic material handling scenarios.
Distributed control system
Distributed I/O control is achieved through Ethernet /IP networks, which is suitable for factory workshops or cross-regional equipment management.
When used in conjunction with the 5069-AEN2TR or 5069-AENTR adapter, it provides flexible remote I/O expansion.
Energy and Public Utilities
In water treatment, power distribution or renewable energy systems, control equipment such as pumps and valves.
It can adapt to harsh environments (such as high temperatures and vibrations) and is suitable for outdoor or industrial site applications.
OEM equipment integration
Provide compact and high-performance control solutions for original equipment manufacturers (Oems), integrated into custom machinery or systems.
Supports multiple programming languages to simplify device development and debugging.
General Industrial Control
It is applicable to HVAC systems, pump station control or other general automation tasks, and supports direct communication with SCADA and HMI systems.
2 MB of memory and 40 Ethernet /IP nodes support a medium-sized control network.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies