Bus IsolatorProduct parameters
General parameters
Module type: Flex Ex Bus Isolator Module
Function: It IS used to interconnect the standard Flex I/O module with the Intrinsically Safe (IS) Flex Ex module to maintain the intrinsically safe integrity of the same I/O group
Number of supported modules: Up to 8 Flex Ex I/O modules are supported at most
Power supply requirements:
Input voltage: 18-32V DC
Current consumption: 150 mA @ 24V DC
Power consumption: Maximum 2.5W
Output power supply: 5.75V DC (provided to the Flex Ex module)
Isolation
Provide electrical isolation from Flexbus to Flexbus (in compliance with DIN EN 60079-11 standard)
Provide electrical isolation from the Flexbus to the Slave Side
Installation method: DIN rail or panel installation
Protection grade: IP20 (For indoor use, protected from water and dust)
Operating temperature: -20°C to 70°C
Storage temperature: -40°C to 85°C
Relative humidity: 5% to 95% (non-condensing)
Connection cable: Supports 1794-CE1 (up to 0.3m) and 1794-CE3 (up to 1m) cables
Certification:
North America: Class I Division 1 & 2, Groups A-D; Class I Zone 1 & 2, Groups IIC, IIB, IIA
Europe: Complies with EN 50020 standard and is applicable to hazardous areas of Zone 0, 1, 2, 21, 22
Others: C-TICK, CE, CUL, KC, MARINE, NRTL, UL
Physical and electrical characteristics
Terminal torque: 7-9 inches - pounds (Ensure the correct torque when wiring)
Power indicator: The module is equipped with a status indicator light for easy diagnosis
Function
Intrinsically safe isolation
Provide electrical isolation between the standard Flex I/O module and the Flex Ex module to ensure that the intrinsically safe circuit complies with the safety requirements of hazardous areas (such as EN 50020 and DIN EN 60079-11).
Prevent non-intrinsically safe signals from passing through the Flex Ex backplane to protect system integrity.
Module interconnection
Standard Flex I/O modules and Flex Ex modules are allowed to coexist on the same DIN rail and be connected to the same adapter (such as the 1797-ACNR15 ControlNet adapter), supporting hybrid system configurations.
Support up to 8 Flex Ex I/O modules to expand the system capacity.
Compatibility
Supports protocols such as ControlNet, DeviceNet, EtherNet/IP, etc. (via adapter).
Compatible with controllers such as FlexLogix and ControlLogix.
Safety design
It must be installed in a safe area or Zone 2 area. When connected to intrinsically safe circuits, relevant regulations (such as German DIN VDE 0165) must be followed.
Power-off/power-on should be synchronized with the adapter to avoid damage or safety risks.
Installation and maintenance
Supports DIN rail installation and is equipped with a locking mechanism to meet the requirements of shock resistance and vibration resistance (DIN rail lock is required).
It is equipped with a removable power connector and a backplane connector for easy installation and maintenance.
Application scenarios
Petrochemical and oil and gas industry: In Class I Zone 0, 1, 2 or European Zone 0, 1, 2, 21, 22 hazardous areas, connect intrinsically safe devices (such as sensors, actuators) to standard Flex I/O systems to ensure safety and compliance.
Chemical engineering and pharmaceuticals: Used in corrosive or explosive gas environments, it connects NAMUR sensors or intrinsically safe I/O modules to monitor and control chemical reaction processes.
Distributed control system: In large factories, it serves as the interface for intrinsically safe I/O systems, connecting equipment in remote hazardous areas to the central control system.
Hybrid I/O system: In scenarios where both standard Flex I/O and Flex Ex modules need to be used simultaneously, it provides isolation and interconnection functions to optimize the system design.
Automation of hazardous environments: Applicable to scenarios requiring intrinsically safe certification, such as mines, oil fields or dust environments (Class II/III), to ensure the safe operation of equipment.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies