1794-AENTR Allen-Bradley Rockwell Flex I/O EtherNet/IP Redundant Adapter Module
1794-AENTR is a Flex I/O dual-port EtherNet/IP adapter module designed for use in industrial control systems.
HS CODE : 8538909200
Product No :
1794-AENTR 1794AENTRManufacture :
Allen BradleySize (cm) :
9 * 9 * 9Weight (kg) :
0.3Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
Adapter ModuleProduct parameters
Module type: Flex I/O Dual-port EtherNet/IP Communication Adapter Module (Dual Port EtherNet/IP Adapter Module
Series: Allen-Bradley 1794 Flex I/O series
Communication protocol: EtherNet/IP, supporting dual-port redundant media
Communication rate: 10/100 Mbps (Supports half-duplex/full-duplex)
Connection method: Dual RJ45 ports, supporting linear, Ring (DLR, Device Level Ring) and star network topologies
Recommended cable: Category 5 Shielded Twisted Pair (STP)
I/O capacity: Supports up to 8 Flex I/O modules (any combination of digital, analog or special modules is supported)
Power supply:
Input voltage range: 19.2-31.2V DC (including 5% AC ripple)
Nominal voltage: 24V DC
Input current: 400 mA (at 24V DC)
Surge current: 18 A (lasting for 2 ms)
Output to the backplane: 5V DC, 640 mA (to power the adjacent Flex I/O module)
Power dissipation
Maximum power dissipation: 6.1 W (at 19.2V DC)
Maximum heat dissipation: 20.8 BTU/ hour (at 19.2V DC)
Isolation
Power to EtherNet: 1000V AC (1 minute)
Environmental conditions:
Operating temperature: 0 to 55°C (32 to 131°F)
Storage temperature: -40 to 85°C (-40 to 185°F)
Relative humidity: 5-95% (non-condensing)
Vibration: 5 g (10-500 Hz, IEC 68-2-6)
Impact: 30g during operation, 50g when not in operation
Protection grade: IEC IP20 (Open type, no enclosure, needs to be installed in an appropriate protective cabinet)
Installation method: DIN rail installation
Installation requirements: It is recommended to leave 5 cm (approximately 2 inches) of space around the module to ensure ventilation and wiring.
Terminal type: Detachable screw terminal. The recommended cable is 0.33-3.31 mm² (22-12 AWG) stranded copper wire, insulation class 75°C (167°F) or higher, maximum insulation thickness 1.2 mm (3/64 inches)
Status indication: Dual-color LED indicator lights are used to display the module status, network status, and the status of Link 1 and Link 2
Module/network status: Green indicates normal, red indicates fault
Link 1/Link 2 status: Yellow flashing indicates 10 Mbps, and green indicates 100 Mbps
Certification: CE, UL, CSA, FM, ATEX, IECEx (Hazardous Location certification, product label confirmation required)
Certification date: As of March 17, 2025 (For specific certification, please check the product label.)
Firmware: Supports firmware version 2.012 (Series A) or higher. Updates need to be downloaded from the Rockwell Automation website
Function
EtherNet/IP communication
Supports dual-port EtherNet/IP, is compatible with Device Level Ring (DLR) topology, and provides network redundancy to improve system availability.
Supports 10/100 Mbps communication rate, half-duplex/full-duplex mode, suitable for real-time data transmission and control.
It is configured through RSLinx and Studio 5000 Logix Designer to support RSNetWorx for EtherNet/IP network diagnosis.
I/O extension
Up to 8 Flex I/O modules can be connected, supporting digital input/output, analog input/output or special modules (such as counters, thermocouple modules), flexibly adapting to various application requirements.
Provide the backplane power supply (5V DC, 640 mA) to power the adjacent Flex I/O modules.
Status monitoring
It is equipped with dual-color LED indicator lights to display the Module status (Module), Network status (Network), and Ethernet connection status (Link 1/Link 2), facilitating rapid diagnosis.
Support network diagnostic function to monitor the health status of EtherNet/IP networks and modules.
Redundant network support
The dual RJ45 ports support DLR topology. When a single point of failure occurs in the network, the path can be automatically switched to ensure communication continuity.
It also supports linear or star topologies, suitable for different network architectures.
Compact design
The module integrates communication adapter and power conversion functions, simplifying the design of distributed I/O systems and reducing wiring and space requirements.
DIN rail mounting, suitable for control cabinets with limited space.
Easy to configure and maintain:
Supports automatic device replacement (ADR), facilitating module replacement and maintenance.
Online configuration and firmware update can be carried out through Studio 5000 Logix Designer or RSLogix 5000 (version 20 or higher).
Application scenarios
Distributed Control System (DCS)
Communicate with Allen-Bradley's Logix controllers (such as ControlLogix, CompactLogix) or other EtherNet/ IP-compatible devices via EtherNet/IP networks, and is suitable for distributed I/O expansion in large factories or production lines.
It is suitable for scenarios that require network redundancy, such as the automotive manufacturing, petrochemical, and food and beverage industries.
Machine control
It is used to monitor and control I/O signals in mechanical equipment, such as driving solenoid valves, relays or monitoring the status of sensors.
It is commonly found in packaging machines, conveying systems, assembly lines and other equipment.
Process control: Applied in industries such as chemical engineering, oil and gas, and water treatment, it connects analog or digital I/O modules to monitor and control process variables (such as temperature, pressure, and flow rate).
The DLR topology ensures high availability and is suitable for critical process control.
Application in hazardous locations: The module has passed ATEX and IECEx certifications and is suitable for some hazardous environments.
Building automation: It is used in building management systems to connect I/O modules to control HVAC, lighting or security systems.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.