1756-IB16D Allen Bradley Rockwell ControlLogix Digital I/O Module
1756-IB16D is a digital input module that is part of the ControlLogix family of I/O modules.
HS CODE : 8538909200
Product No :
1756-IB16D 1756IB16DManufacture :
Allen BradleySize (cm) :
14 * 8* 14Weight (kg) :
1Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
I/O ModuleProduct parameters
Input channel:
Quantity: 16 digital input channels, divided into 4 groups, with 4 channels in each group.
Input type: DC digital input (current Sinking, Sinking).
Voltage category: 12/24V DC.
Working voltage range: 10-30V DC.
Nominal input voltage: 24V DC.
Isolation: Input to the backplane isolation, inter-group isolation (4 points per group), no inter-channel isolation.
Electrical characteristics:
Open-state current
Minimum 2 mA @ 10V DC.
Maximum 13 mA @ 30V DC.
Closed-state characteristics:
Maximum voltage: 5V DC.
Maximum current: 1.5 mA.
Surge current: Maximum 250 mA, duration decays to below 37% within 22 ms without activation.
Backplane current
5.1V DC: 150 mA.
24V DC: 3 mA.
Total backplane power: 0.84 W.
Power dissipation: Maximum 5.8W at 60°C.
Heat dissipation: 19.78 BTU/ hour at 60°C.
Isolation voltage: 250V (continuous), basic insulation type, input to the backplane and isolation between groups.
Input delay time:
OFF to ON
Hardware latency: Nominal 340 µs, maximum 1 ms.
Users can configure the filtering time: 0, 1 or 2 ms.
ON to OFF
Hardware latency: Nominal 740 µs, maximum 4 ms.
Users can configure the filtering time: 0, 1, 9 or 18 ms.
Diagnostic function:
Disconnection detection: Supports Wire off Diagnostics on the field side, but does not display the status of fuse breakage or fuse removal.
Timestamp: The resolution of the diagnostic timestamp is 1 ms, which is used to record the time when the fault occurs or is cleared.
Pulse testing: Supports pulse testing to verify input integrity.
No-load detection: Detect whether the input channel is connected to a load.
Physical properties:
Installation method: Rack-mounted, compatible with ControlLogix racks (such as 1756-A4, A7, A10, A13, A17).
Terminal block: Compatible with detachable terminal blocks (RTB), such as 1756-TBCH (36-pin screw terminal) or 1756-TBS6H (36-pin spring clip terminal).
Pre-wired cables: Support Bulletin 1492 pre-wired cables (such as 1492-IFM40F, 1492-IFM40D24A-2).
Enclosure type: Open type (IP20 protection grade).
Display: The front panel of the module is equipped with 16 I/O status LED indicator lights (yellow indicates input activation, red indicates fault), as well as an OK status indicator light (green indicates normal, flashing red indicates communication issue, and red indicates module fault).
Environmental conditions:
Operating temperature: 0°C to 60°C
Storage temperature: -40°C to 85°C.
Relative humidity: 5% to 95% (non-condensing).
Vibration: 2G (10-500 Hz).
Operating impact: 30G.
Non-operational impact: 50G.
Surge immunity: The signal port can withstand a 1 kV line to ground surge.
Certification:
Compliance standards: CE, UL, CSA, C-Tick, CCC, KC, MARINE, RCM (Specific certifications need to be checked on the product label as the date of manufacture may vary).
Programming and Configuration
Compatible software: Studio 5000 Logix Designer, used for module parameter setting, diagnostic monitoring and programming.
Function
Diagnostic function:
It provides channel-level diagnostics, including disconnection detection, no-load detection and pulse testing, suitable for applications that require high reliability and troubleshooting.
Supports a timestamp with a resolution of 1 ms for recording input state changes or fault events, facilitating sequential event (SOE) applications.
Diagnostic data can be monitored through Module Info, including module faults, backplane status and input point status.
Medium-density input
It provides 16 DC input channels (10-30V DC), divided into 4 groups (4 points in each group), suitable for medium-density input scenarios. Compared with 1756-IB32 (32 channels), it is more suitable for smaller-scale applications.
Flexible communication format:
Support multiple data formats:
Standard input data format: Return fault and input data.
CST timestamp input data format: Return the input data and the changed timestamp.
Rack-optimized data format: Collect digital word data from remote racks and convert it into rack images.
Only listen in mode (including standard, CST timestamp and rack-optimized format).
Input information and output status can be shared with the ControlLogix controller via EtherNet/IP or ControlNet network, and it supports Producer/Consumer technology.
Status monitoring
Equipped with LED diagnostic indicator lights:
OK indicator light: Green indicates normal operation, flashing red indicates communication issues, and red indicates that the module needs to be replaced.
16 I/O status indicator lights: yellow indicates input activation, and red indicates input failure.
Support user-configurable filtering time, optimize input signal processing, and adapt to fast switching or noise reduction requirements.
Modular design
Supports Removal and Insertion Under Power (RIUP, Removal and Insertion Under Power), facilitating maintenance.
Connect the on-site wiring via RTB (1756-TBCH or 1756-TBS6H) or 1492 interface modules (IFM) to simplify installation and replacement.
Support Electronic Keying to prevent incorrect module replacement.
Support multiple input devices:
Compatible with a variety of DC input devices, such as buttons, limit switches, proximity sensors, relay contacts, etc., and supports Sinking configuration.
It can be used directly with 24V DC signals. If AC signals are used, appropriate intermediate circuits need to be installed.
High reliability
The design meets the requirements of industrial environments, is resistant to high temperatures, high humidity and vibration, and is suitable for harsh environments.
Inter-group isolation and isolation to the backplane input reduce the risk of electrical interference and enhance system stability.
Application scenarios
Manufacturing industry: It is used to monitor digital signals on production lines, such as the status of buttons, proximity sensors or limit switches, and is suitable for automotive manufacturing, packaging lines or electronic assembly.
Process control
It is applied in the chemical, petroleum and natural gas, pharmaceutical and food and beverage industries to monitor the on/off signals of switches, valves or other equipment.
The diagnostic function is suitable for process control systems that require high reliability and fault tracking, such as pumping stations or piping systems.
Safety interlock
Detect the status of the emergency stop button or safety sensor in the safety system, trigger the safety shutdown or interlock operation, and the diagnostic function ensures the reliability of the signal.
Sequential Event Recording (SOE) :
The 1 ms timestamp resolution makes it suitable for applications that require precise recording of the sequence of events, such as power systems or critical mission monitoring.
Counting application: It is used for counting objects passing through sensors, such as product counting on production lines, and is suitable for medium-speed input signal processing.
Distributed control system: Integrated into the distributed I/O system via EtherNet/IP or ControlNet network, it is suitable for large factories or remote monitoring applications, such as the PlantPAx DCS platform.
Traditional system maintenance: 1756-IB16D is often used for the maintenance or expansion of existing ControlLogix systems, especially suitable for scenarios that require diagnostic functions.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies