1734-IE8C Allen Bradley Rockwell CompactLogix 5370 Analog I/O Module
1734-IE8C is a POINT I/O 8 channel high density current input module that operates with a 24V DC input voltage.
HS CODE : 8538909200
Product No :
1734-IE8C 1734IE8CManufacture :
Allen BradleySize (cm) :
5.6 * 7.6 * 1.2Weight (kg) :
0.04Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
I/O ModuleProduct parameters
Module type: POINT I/O Analog Current Input Module
Number of input channels: 8 single-ended, non-isolated current input channels
Input current range:
0-20 mA or 4-20 mA (configurable by the user)
Maximum input range: 0-21 mA
Resolution: 16 bits (across 0-21 mA, approximately 0.32 μA/ count)
Data format: Signed integer (-32,767 to +32,767)
Input impedance: 60 Ω
Absolute accuracy: 0.1% full scale @ 25°C (77°F)
Temperature drift: 30 ppm/°C
Conversion type: Delta-Sigma analog-to-digital conversion
Power supply:
External DC power supply voltage range: 10-28.8V DC, nominal 24V DC
Maximum POINTBus current: 75 mA @ 5V DC
Power consumption:
Maximum power dissipation: 0.75 W @ 28.8V DC
Maximum heat dissipation: 2.5 BTU/hr @ 28.8V DC
Isolation voltage: 50V (continuous), test voltage is 2550V DC for 60 seconds
Overload protection: Internal overload protection, up to 28.8V DC
Installation method: DIN rail installation (It is recommended to use galvanized yellow chromium steel rail)
Wiring method: Detachable terminal block (RTB), it is recommended to use 0.25-2.5mm ² (22-14 AWG) solid or stranded shielded copper wire, rated temperature 100°C (212°F), insulation thickness 1.2mm
Terminal screw torque: 0.8 N·m (7 lb·in)
Operating temperature range: -20°C to 55°C (-4°F to 131°F)
Protection grade: Open type (no enclosure, IP20)
Key switch position: 3
Supported networks: ControlNet, DeviceNet, EtherNet/IP and other open networks
Certification standards: C-TICK, CCC, CE, CUL, GOST, KC, MARINE, UL
Function
Analog current input processing
Supports 8 single-ended, non-isolated current input channels, receiving 0-20 mA or 4-20 mA analog signals.
The analog signal is converted into a 16-bit signed integer through the Delta-Sigma converter, which is suitable for high-precision data processing.
High-density design: It provides 8 input channels and is the analog input module with the highest channel density in the POINT I/O series, optimizing space utilization.
Diagnostic function:
Support channel-level diagnosis, including over-range/under-range detection and electronic position status feedback.
It provides channel-level data alarm (with 4 set points for each channel), facilitating fault detection and system maintenance.
Flexible configuration
Supports scaling of engineering units, allowing users to convert raw data into actual physical quantities.
The input range and alarm threshold can be configured through the software to adapt to various application requirements.
Modular design
Compatible with POINT I/O communication adapters and supporting distributed I/O architectures.
Detachable terminal blocks (RTB) simplify wiring and maintenance.
Compact and efficient
Compact in size, it is suitable for control cabinets with limited space.
Low-power design (0.75W) reduces energy consumption.
Status monitoring: Equipped with status indicator lights for modules, networks and each channel, it facilitates real-time monitoring and fault diagnosis.
Supports multiple devices: Compatible with 2-wire and 4-wire transmitters, suitable for a variety of industrial sensors and instruments.
Application scenarios
Industrial automation: It is used in PLC or PAC systems to receive current signals from transmitters, sensors or instruments, and monitor process variables such as pressure, liquid level, flow rate, temperature, speed, viscosity, turbidity, pH, conductivity and vibration.
Process control: In industries such as chemical engineering, oil and gas, pharmaceuticals, and water treatment, high-precision analog signals are processed to achieve process monitoring and control.
Manufacturing industry: In industries such as automotive manufacturing, food and beverage, and packaging machinery, it is used to monitor and control key parameters on the production line.
Distributed I/O system: In large factories or facilities, combined with POINT I/O communication adapters, it reduces wiring costs and enhances system scalability.
High-density signal acquisition: Suitable for application scenarios that require simultaneous monitoring of multiple analog signals, such as multi-point temperature or pressure monitoring.
Closed-loop control: By receiving analog signals and combining with the PID control algorithm, a fully automatic closed-loop control system is achieved, such as flow regulation or liquid level control.
Space-constrained environments: The compact design makes it suitable for installation on small control cabinets or DIN rails close to on-site equipment.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies