1734-IE2C Allen-Bradley POINT I/O 2-Channel Analog Current Input Module
1734-IE2C is an analog input module manufactured by Allen-Bradley.
HS CODE : 8538909200
Product No :
1734-IE2C 1734IE2CManufacture :
Allen BradleySize (cm) :
5 * 1 * 8Weight (kg) :
0.04Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
I/O ModuleProduct parameters
Module type: POINT I/O 2-channel analog Current Input module
Input channels: 2 single-ended, non-isolated current input channels
Input signal range:
0-20 mA
4-20 mA (default configuration, suitable for standard industrial sensors)
Resolution: 16 bits (0.32 μA/bit)
Input impedance: 100 Ω
Accuracy: ±0.1% full range @ 25°C
Conversion time: Approximately 8 ms per channel
Power supply requirements:
Backplane power supply: 24V DC (nominal), 10-28.8V DC
Backplane current consumption: 75 mA @ 24V DC
On-site power supply: Provided via 1734-FPD or adapter (such as 1734-ADN), up to 10 A
Power consumption: 0.6W @ 28.8V DC (maximum value)
Heat dissipation: 2.0 BTU/hr @ 28.8V DC (maximum value)
Isolation voltage: 50V (continuous), test withstand 2550V DC for 60 seconds (isolation between channels and backplane, no isolation between channels)
Operating temperature: -20°C to 55°C (-4°F to 131°F)
Storage temperature: -40°C to 85°C (-40°F to 185°F)
Humidity: 5% to 95% (non-condensing)
Installation method: DIN rail installation, side by side with the POINT I/O module
Enclosure type: Open type (Recommended for installation in a cabinet with IP54 or higher protection level)
Certification: UL, cULus, CE, C-Tick, in compliance with industrial standards
Software support: RSLogix 5000 or Studio 5000 (for configuration and data integration), RSNetWorx for DeviceNet (for network configuration)
UPC/GTIN: 10612598206879 (Series C)
Installation method: DIN rail installation, side by side with other POINT I/O modules (such as 1734-ADN, 1734-FPD), sliding connection, convenient for installation and disassembly
Function
Analog signal acquisition: Supports 2 single-ended current input channels (0-20 mA or 4-20 mA) to collect analog signals from sensors or transmitters.
High-precision measurement: 16-bit resolution (0.32 μA/bit) and ±0.1% accuracy ensure precise data acquisition.
Flexible configuration: Configure the input range, filtering time and alarm Settings through RSLogix 5000 or Studio 5000.
Network integration: Communicate with the PLC through an adapter, supporting data exchange modes such as polling and status change.
Diagnostic function: It provides status LED and software diagnosis for easy troubleshooting.
Modular design: Seamless integration with the POINT I/O system and support flexible expansion.
Application scenarios
Process control: In the chemical, water treatment or oil and gas industries, 4-20 mA signals from pressure, flow or temperature transmitters are collected.
Production line automation: In automotive manufacturing or packaging lines, sensor signals (such as liquid level and flow rate) are monitored and integrated with PLCS (such as 1756-L65).
Distributed I/O system: Through 1734-ADN or 1734-AENTR, it cooperates with ControlLogix or SLC 500 PLC to manage distributed analog inputs.
Equipment monitoring: Combined with XM modules (such as 1440-VST02-01RA), it monitors analog signals of rotating machinery (such as vibration and eccentricity).
Hybrid control system: Integrated with PowerFlex drivers (such as those equipped with 20-750-DENC-1) or medium-voltage MCC (such as 1503VC-BMC4) through the DeviceNet network to coordinate control and monitoring.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
MC-ZAOYF2 |
50047099-501 |
900H03-0202 |
MC-ZDISF2 |
51205995-501 |
900H32-0302 |
MC-ZDIXF2 |
51451432-010 |
900J02-0001 |
MC-ZDIYF2 |
51451432-020 |
900J10-0001 |
MC-ZDOXF2 |
51452262-501 |
900K01-0201 |
MC-ZDOYF2 |
51500638-501 |
900ME1-0060-00 |
MC-ZLLAI2 |
900B16-0202 |
900ME1S-0060-00 |
MC-ZLLMF2 |
900C30S-0360-00 |
900P01-0501 |
MC-ZRHMF1 |
900C50S-0360-00 |
900P01-0601 |
MC-ZSTXF3 |
900C50S-0460 |
900P01-0701 |
50008930-001 |
900C51-0243-00 |
900P01-0801 |
50038816-501 |
900C70-0460 |
900P02-0101 |
50038816-502 |
900C70S-0460 |
900P24-0401 |
50038817-001 |
900C75-0560 |
900P24-0501 |
50038818-501 |
900C75S-0460 |
900P24-0601 |
50038820-501 |
900C75S-0560 |
900R01-0300 |
50040636-002 |
900G04-0101 |
900R04-0300 |
50047098-001 |
900G32-0301 |
900R08-0200 |
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies