1788-CN2DN Allen-Bradley Network Linking Device Communications Adapter
1788-CN2DN is a linking device designed to connect a ControlNet network to a DeviceNet network.
HS CODE : 8538909200
Product No :
1788-CN2DN 1788CN2DNManufacture :
Allen BradleySize (cm) :
20 * 12 * 9Weight (kg) :
0.7Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
Adapter ModuleProduct parameters
General parameters
Module Type: Linking Device from ControlNet to DeviceNet
Product Number: 1788-CN2DN (Series may be A or B)
Protection grade: IP20 (Open type, needs to be installed in a protective cabinet)
Operating temperature: 0°C to 60°C (32°F to 140°F)
Storage temperature: -40°C to 85°C (-40°F to 185°F)
Relative humidity: 5% to 95% (non-condensing)
Working impact: 30g (DIN rail or panel mounting, IEC 68-2-27)
Vibration resistance: 2 g (10-500 Hz, IEC 68-2-6)
ESD immunity: 6 kV (contact discharge), 8 kV (air discharge, in compliance with IEC 61000-4-2)
Temperature code: T4A (North America), T4 (IEC)
Certifications: ATEX, China CCC, UKCA, UL, C-UL, CE
Electrical parameters
Input power supply: 18-32V DC, nominal 24V DC (Class 2 or SELV)
Maximum input current: 400 mA @ 24V DC
Power consumption: Maximum 9.6W
Wire requirements:
Power connection: 0.25- 2.5mm ² (22-14 AWG), solid or stranded copper wire, insulation class ≥75°C (167°F), maximum insulation thickness 1.2mm (3/64 inches)
DeviceNet connection: 1485C-P1-Cxxx cable, 0.52mm ² (20 AWG)
ControlNet connection: RG6 coaxial cable
Connector
Two BNC coaxial ControlNet connectors
1 DeviceNet 10-pin linear connector (supports 5-pin or micro connectors, to be purchased separately)
One 5-pin Phoenix power connector
Communication parameters
ControlNet Protocol: Supports ControlNet networks and requires "Active Keeper" for network scheduling and clock synchronization
DeviceNet protocol: Supports data rates of 125K, 250K, and 500K bps (set via one rotary switch)
Node address: 4 DeviceNet node address switches (0-63)
Maximum number of connections: Supports up to 64 DeviceNet nodes
Compatibility
Supported controllers: PLC-5, SLC 500, CompactLogix, ControlLogix (For example, Logix5550 requires the 1756-CNB module)
Supported devices: DeviceNet adapters (such as POINT I/O, Flex I/O), Series 9000 Photoeye, 855T Stack Light, 1792D-VT0D Maxum Block, Bulletin 160 Drive, etc
Software requirements: RSLinx 2.10 or higher, RSLogix 5000 (Add-On Profile integration), RSNetWorx for ControlNet/DeviceNet
Function
Network bridging
As a bridge between the ControlNet and DeviceNet networks, it supports data exchange.
Allow ControlNet devices (such as PLC-5, ControlLogix controllers) to communicate with DeviceNet devices (such as I/O adapters, sensors).
High-performance communication
ControlNet offers highly deterministic and repeatable data transmission, making it suitable for time-critical I/O and interlocked data.
DeviceNet supports data rates of 125K, 250K and 500K bps, adapting to different network requirements.
Easy to configure
Automatically identify and configure devices through the Add-On Profile of the RSLogix 5000 to simplify integration.
The rotary switch sets the DeviceNet data rate, and the node address switch sets the network address.
Diagnosis and Monitoring
It provides multiple LED status indicator lights to monitor the network status of ControlNet/DeviceNet, I/O status and module health status.
Supports RSNetWorx for network diagnosis, but cannot directly display the DeviceNet status code (which needs to be viewed through the connected DeviceNet scanner).
High reliability
Supports DIN rail or panel installation, with an IP20 protection rating, suitable for industrial environments.
The 30g working impact and wide temperature range (0-60°C) ensure stability.
Flexible connection
Supports up to 16 DeviceNet devices, reducing the need for external power regulators.
Open 10-pin or 5-pin DeviceNet connectors are provided, compatible with various cable types.
Application scenarios
Manufacturing industry: Connect the PLC-5 or ControlLogix controller with the DeviceNet I/O module (such as POINT I/O) to achieve production line control.
Process control: In the chemical and food and beverage industries, connect HMI and DeviceNet devices (such as 855T Stack Light) to monitor process data.
Traditional system upgrade: Integrate the ControlNet network of the old PLC-5 system (including 1785-L40L) with DeviceNet devices to expand functions.
Distributed control: Connect the controller and remote DeviceNet devices through ControlNet, supporting distributed I/O.
Data acquisition: Collect sensor data from DeviceNet devices (such as Series 9000 Photoeye) and transfer it to the SCADA system of ControlNet.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies