1785-ME32 Allen-Bradley Enhanced PLC-5/30 EEPROM Memory Module
1785-ME32 is a memory module designed for use with the PLC-5 programmable logic controller from Rockwell Automation.
HS CODE : 8538909200
Product No :
1785-ME32 1785ME32Manufacture :
Allen BradleySize (cm) :
14 * 7 * 1Weight (kg) :
0.9Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
Memory ModuleProduct parameters
Module type: EEPROM (Electrically Erasable Programmable Read-Only Memory) storage module
Storage capacity: 32K words, used for storing user programs and data
Compatible processors: PLC-5 series processors, including but not limited to:
1785-L20B, 1785-L30B, 1785-L40B, 1785-L40L, 1785-L60B, 1785-L60L
1785-L80B, 1785-L80C (the processors you mentioned earlier)
Other PLC-5 enhanced processors (such as 1785-L26B, 1785-L46B, etc.)
Storage type: Non-volatile storage, supporting the permanent preservation of programs and data
Write/erase cycle: EEPROM supports a limited number of write/erase cycles (typically 10,000 times), so frequent writes should be handled with caution
Installation location:
Insert the dedicated storage module slot for the PLC-5 processor (usually located on the front of the processor module)
It does not occupy the slot of the 1771 I/O rack
Power consumption: No additional backplane current requirement
Operating temperature: 0 to 60°C (32 to 140°F)
Storage temperature: -40 to 85°C (-40 to 185°F)
Relative humidity: 5% to 95% (no condensation)
Environmental protection: Open enclosure (IP00), must be installed in a cabinet that complies with NEMA standards to protect against dust, moisture or corrosive gases
Certification: Complies with CE, UL, CSA and other standards (consistent with the certification of processor modules)
Indicator: There is no independent status indicator light. It relies on the status display of the processor module
Function
Non-volatile storage
It provides 32K words of non-volatile storage space for saving user programs, ladder diagram logic, data tables and configuration data, which can retain data even in the event of power failure or battery failure.
Avoid relying on battery backups (such as 1770-XYC lithium batteries) to enhance system reliability.
Program Backup and recovery
Support writing the RAM content of the PLC-5 processor (such as 1785-L80C) to 1785-ME32, or loading it from 1785-ME32 into the processor RAM for convenient program backup, recovery or cross-device migration.
Perform storage operations through programming software (such as RSLogix 5 or Studio 5000 Logix Designer).
Fast program loading
It allows for the rapid loading of pre-stored programs into the processor, reducing system startup time and is suitable for scenarios where programs need to be frequently replaced.
Modular design
Insert directly into the storage module slot of the PLC-5 processor without the need for additional wiring or backplane power supply, simplifying installation and maintenance.
Compatibility
Compatible with a variety of PLC-5 processors and suitable for Enhanced, ControlNet and Ethernet series processors.
It supports use in conjunction with 1771 I/O racks and modules to build a complete control system.
Data protection
EEPROM technology ensures that data is not lost after power failure, making it suitable for long-term operation or critical mission applications.
It can be protected through the processor Settings program (such as prohibiting changes) to prevent unauthorized modifications.
Application scenarios
Manufacturing plant
In automotive manufacturing, food processing or electronic assembly production lines, complex ladder diagram programs are stored to ensure that the control logic remains intact after power failure or battery replacement.
Supports rapid program switching and is suitable for flexible configuration on multi-product production lines.
Process control
In the chemical, oil and gas or pharmaceutical industries, key process control programs are preserved to ensure system reliability.
It is suitable for scenarios that require long-term storage of data tables, such as formula management or historical records.
Energy Management
In power distribution or renewable energy systems, control logic and configuration data are stored to ensure the stable operation of switchgear or monitoring devices.
Suitable for critical mission environments, it reduces the risk of program loss caused by battery failure.
Material handling
In warehousing or logistics systems, control programs for automated sorting, conveying or stacking equipment are saved to support rapid system recovery.
Legacy system maintenance
It is used to maintain the old system based on PLC-5 and extend the system life through EEPROM storage.
It is suitable for backing up old system programs and preparing for migration to modern platforms such as ControlLogix.
Remote or harsh environments: In remote facilities or harsh environments (such as high temperature, low temperature or high humidity), EEPROM offers a more reliable storage solution than battery backup.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies