1785-ENET Allen-Bradley PLC5 Ethernet Interface Module
1785-ENET is a communication module designed for use with the PLC-5 programmable logic controller from Rockwell Automation.
HS CODE : 8538909200
Product No :
1785-ENET 1785ENETManufacture :
Allen BradleySize (cm) :
31 * 11 * 16Weight (kg) :
0.77Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
Interface ModuleProduct parameters
General parameters
Module type: EtherNet/IP Interface Module
Product Number: 1785-ENET
Number of ports: 1 RJ45 Ethernet port (supporting TCP/IP protocol)
Installation method: Insert into the 1771 general-purpose I/O rack, occupying 1 slot
Protection grade: IP00 (Open type, needs to be installed in a protective cabinet)
Operating temperature: 0°C to 60°C (32°F to 140°F)
Storage temperature: -40°C to 85°C (-40°F to 185°F)
Relative humidity: 5% to 95% (non-condensing)
Vibration resistance: 2 g (10-500 Hz, IEC 68-2-6)
Seismic resistance: 30 g (running), in accordance with IEC 68-2-27
Certification: C-Tick, CE, UL, C-UL (Applicable to Class I, Division 2, Groups A, B, C, D or non-hazardous areas)
UPC: 612598169207
GTIN: 10612598169204
Electrical parameters
Backplane power supply: 5V DC, 1.0A (typical value, some materials mention 2.2A)
Power consumption: 5 W (maximum), heat dissipation 37.54 BTU/ hour
Isolation voltage: 50V (Basic insulation, communication to the system, test voltage 500V AC, 60 seconds)
Wire requirements: Shielded or unshielded twisted pair (STP/UTP), in compliance with Ethernet 802.3 standard
Network parameters
Communication protocol: EtherNet/IP (Based on TCP/IP)
Transmission rate: 10/100 Mbps (Automatic negotiation)
Maximum number of connections: 64 concurrent connections, 512 definitions/modules
Status indicator light:
STAT: Ethernet link activity status of the module
10M: 10 Mbps network connection
100M: 100 Mbps network connection
Supported functions: Point-to-point communication, Web diagnosis, SNMP (Simple Network Management Protocol)
Compatibility
Supported controllers: PLC-5 series (such as 1785-L20E, L40E, L80E), ControlLogix (via adapter)
Compatible racks: 1771 universal I/O racks (such as 1771-A1B, A2B, A3B, A4B)
Supported software: RSLogix 5, RSLink (for program communication and diagnosis)
Function
EtherNet connection: Provides 10/100 Mbps Ethernet (EtherNet/IP, TCP/IP protocol) connection, supporting communication with HMI, SCADA, DCS or programming devices.
Supports 64 concurrent connections and allows multiple devices to communicate simultaneously
Dual-link support
When used in conjunction with the enhanced PLC-5 controller, it supports the simultaneous operation of Ethernet and DH+/RIO ports.
When used in conjunction with Ethernet PLC-5 controllers (such as 1785-L80E), dual Ethernet links are supported
Plug and play
Automatically negotiate speed and duplex Settings to simplify network configuration.
Support local programming (via DH+ or RS-232 protocol)
Diagnosis and Monitoring
Built-in Web diagnosis and module information service, access PLC-5 data tables and diagnostic information through a standard browser
Supports SNMP for convenient network management and troubleshooting
High reliability
Wide temperature range (0-60°C) and anti-vibration/shock design, suitable for industrial environments.
50V circuit isolation (basic insulation) ensures communication stability
Compatibility
Seamlessly integrated with PLC-5 processors and 1771 I/O racks, it supports distributed I/O and remote programming.
Application scenarios
Manufacturing industry: Used for production line networking, connecting PLC-5 controllers with HMI (such as 2711-M3A18L1) or SCADA systems.
Process control: In the chemical and food and beverage industries, integrate the PLC-5 system with the distributed control system (DCS).
Traditional system upgrade: Add Ethernet functionality to the old PLC-5 system to connect to modern HMI or programming devices.
Distributed I/O: Supports distributed I/O systems and connects remote devices via Ethernet.
Data acquisition and monitoring: Access the PLC-5 data table through Web diagnosis to monitor process data in real time.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies