1771-IAD Allen-Bradley PLC 5 Digital AC/DC Input Module
The 1771-IAD is a Input Module from the Allen-Bradley 1771 series, , 120V AC, 16 Input.
HS CODE : 8538909200
Product No :
1771-IAD 1771IADManufacture :
Allen BradleySize (cm) :
8.9 * 16.5 * 5.1Weight (kg) :
0.8Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
I/O ModuleProduct parameters
Basic information:
Manufacturer: Allen-Bradley (Rockwell Automation)
Model: 1771-IAD (Series B, C, D, etc.)
Type: Digital Input Module
Compatible system: PLC-5 series, installed on the 1771 I/O rack
Installation requirements: It can be installed in any slot except the dedicated slots for processors and adapters, and is compatible with 1771-A1B, A2B, A3B, A3B1, A4B, AM1, and AM2 racks (not compatible with 1771-A1, A2, and A4).
Electrical parameters:
Input channels: 16 input points
Input voltage: 79-138V AC (50/60 Hz), 79-138V DC
Backplane current: 195 mA @ 5V DC
Power dissipation: minimum 1.0W, maximum 8.8W
Heat dissipation: minimum 3.42 BTU/ hour, maximum 30.1 BTU/ hour
Input current:
120V AC (60 Hz) : 9.9 mA
120V AC (50 Hz) : 8.7mA
125V DC: 2.56mA
Maximum off-state current: 3.0 mA (AC), 0.8 mA (DC)
Signal delay
AC conduction: 5 ± 3 ms
DC conduction: 3 ± 0.1 ms or 10 ± 1 ms can be selected
AC/DC disconnection: 25 ± 5 ms
Operating temperature: 0°C to 60°C (32°F to 140°F)
Storage temperature: -40°C to 85°C (-40°F to 185°F)
Relative humidity: 5% to 95% (no condensation)
Connection and wiring:
Wiring arm: 1771-WH (Detachable terminal block, facilitating module replacement without disconnecting the wiring)
Key control positions: 10-12 or 14-16 (to prevent incorrect installation)
Power supply requirements: Power is supplied through the backplane of the 1771 I/O rack. It is necessary to ensure that the total current demand with other modules within the rack does not exceed the power supply.
Others:
Indicator lights: 1 green module activity indicator light, 16 red input status indicator lights (illuminated when voltage exists)
Certifications: c-UL, C-TICK, CE
Support for addressing: Supports 1/2 slot, 1 slot and 2 slot I/O addressing
Function
Discrete input processing
It provides 16 input channels, compatible with 120V AC (50/60 Hz) and 125V DC signals, and is suitable for a variety of discrete devices (such as buttons, limit switches, relay contacts, contactors).
Supports mixed AC/DC input, providing flexibility, but does not support 24V DC or 240V AC signals.
Signal delay adjustment
Equipped with an adjustable delay time jumper (suitable for all 16 channels), it can be selected as 5 ms or 20 ms (AC) and 3 ms or 10 ms (DC) to filter out noise and prevent false detection of input signals.
Modular design
It uses the 1771-WH wiring arm, which supports modular wiring, facilitating installation and maintenance. Modules can be replaced without disconnecting the wiring.
Supports RIUP (Live Plug and unplug) function to reduce downtime.
Status monitoring
The front panel is equipped with 1 green module status indicator light and 16 red input status indicator lights, facilitating real-time monitoring of input signals and module operation status.
The input status is transmitted to the processor through the backplane for reading by the PLC program.
System Integration
Compatible with ControlNet, remote I/O and extended local I/O networks, supports master/slave configuration, and is suitable for distributed control systems.
It can be used in conjunction with the 1771-OA output module to drive the input signal through inductors or resistors (such as RG 1676-1 inductors or 2500-ohm resistors).
High performance and reliability
Provide high-performance local I/O processing, suitable for controlling the entire industrial process.
The module design is durable, suitable for industrial environments, and supports multiple I/O types.
Application scenarios
Industrial Automation
It is used to receive discrete input signals, such as buttons, limit switches, indicator lights, motor starters and alarms, and is widely applied in automated production lines, assembly lines and material handling systems.
It is suitable for scenarios that require high reliability and rapid response, such as automotive manufacturing, packaging equipment and food processing.
Distributed control system
In large factories, decentralized sensor and switch signals are integrated into the central PLC-5 controller through remote I/O or ControlNet networks.
Distributed equipment monitoring applicable to the energy, chemical or water treatment industries.
Traditional system maintenance
It is applicable to the old automation systems based on PLC-5, especially when it is necessary to continue using the existing equipment.
It can be used as a transitional module to support migration to modern ControlLogix systems.
General input application:
Its AC/DC compatibility makes it suitable for mixed-signal environments, such as industrial scenarios where both AC and DC inputs need to be processed simultaneously.
General control tasks suitable for medium and low density I/O requirements.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
FS-IOBUS-CPIO6 |
FS-MB-0001 |
FS-PDC-MB24-1 |
FS-IOBUS-CPIO7 |
FS-MB-0002 |
FS-PDC-MB24-1P |
FS-IOBUS-CPIO8 |
FS-MB-0003 |
FS-PDC-MB24-2 |
FS-IOBUS-CPIOX |
FS-MB-0005 |
FS-PDC-MB24-2P |
FS-IOBUS-CPIOX1 |
FS-MCSET-FSC2SM01 |
FS-PDC-MB24-3 |
FS-IOBUS-CPIOX2 |
FS-PDB-CPX05 |
FS-PDC-MB24-3P |
FS-IOBUS-CPIOX3 |
FS-PDB-IOX05 |
FS-PDC-MBMB-1 |
FS-IOBUS-CPIOX4 |
FS-PDC-ART05 |
FS-PDC-PSU24 |
FS-IOBUS-CPIOX5 |
FS-PDC-CPSET |
FS-PSU-240516 |
FS-IOBUS-CPIOX6 |
FS-PDC-CPX05 |
FS-SICC-0001/L10 |
FS-IOBUS-CPIOX7 |
FS-PDC-FTA24P |
FS-SICC-0001/L15 |
FS-IOBUS-CPIOX8 |
FS-PDC-IOR05 |
FS-SICC-0001/L20 |
FS-IOBUS-CPIOX9 |
FS-PDC-IOR05A |
FS-SICC-0001/L25 |
FS-IOBUS-CPX-1 |
FS-PDC-IOS05 |
FS-SICC-0001/L3 |
FS-IOBUS-CPX-2 |
FS-PDC-IOS05A |
FS-SICC-0001/L30 |
FS-IOBUS-CPX11 |
FS-PDC-IOSET |
FS-SICC-0001/L40 |
FS-IOBUS-CPX12 |
FS-PDC-IOX05-1 |
FS-SICC-0001/L5 |
FS-IOBUS-DEMO |
FS-PDC-IOX05-2 |
FS-SICC-0001/L50 |
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies