1756-IF4FXOF2F Allen Bradley Rockwell Analog Combination Module
1756-IF4FXOF2F is a ControlLogix module.
HS CODE : 8538909200
Product No :
1756-IF4FXOF2F 1756IF4FXOF2FManufacture :
Allen BradleySize (cm) :
13 * 11 *5Weight (kg) :
0.37Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
I/O ModuleProduct Parameters
Basic Information:
Manufacturer: Allen-Bradley (Rockwell Automation)
Model: 1756-IF4FXOF2F (Series A)
Type: High-Speed Analog Combination Input/Output Module
Compatible Systems: ControlLogix series (compatible with PLC-5 via adapters)
Installation: Occupies one slot in a 1756 ControlLogix chassis, suitable for local or distributed I/O configurations
Module Location: Can be installed in any slot of the ControlLogix chassis
Electrical Parameters:
Input Channels:
Number: 4 high-speed, sub-millisecond, differential inputs
Input Signal Ranges:
Voltage: ±10V, 0–10V, 0–5V
Current: 0–20 mA (commonly 4–20 mA)
Resolution:
Voltage: 14 bits across ±10.5V (1.3 mV/bit), 0–10.5V (1.3 mV/bit), 0–5.25V (650 µV/bit)
Current: 14 bits across 21 mA (2.8 µA/bit)
Overvoltage Protection: 30V DC (voltage), 8V AC/DC (current)
Open Circuit Detection: Positive full-scale reading within 1 second (current mode)
Input Impedance:
Voltage: >10 MΩ
Current: 249 Ω
Output Channels:
Number: 2 high-speed voltage or current outputs
Output Signal Ranges:
Voltage: ±10V
Current: 0–20 mA (commonly 4–20 mA)
Resolution:
Voltage: 14 bits across 21.8V (1.3 mV/bit)
Current: 13 bits across 21 mA (2.8 µA/bit)
Short-Circuit Protection: Electronically limited to 21 mA or less
Overvoltage Protection: 24V DC
Open Circuit Detection: Limited to current output, requires >0.1 mA
Drive Capability:
Voltage: >2000 Ω
Current: 0–700 Ω
Backplane Current:
375 mA @ 5.1V DC
100 mA @ 24V DC
Backplane Power: 4.3 W (total)
Power Dissipation:
Voltage: 4.3 W
Current: 4.7 W
Thermal Dissipation:
Voltage: 14.66 BTU/hour
Current: 16.02 BTU/hour
Update Period: Minimum 300 µs (sub-millisecond channel scans)
Isolation Voltage: 50V continuous (channel-to-backplane), tested at 1500V AC for 60 seconds (basic insulation)
Connection and Wiring:
Removable Terminal Blocks (RTBs):
1756-TBCH: 36-position Cage-Clamp block
1756-TBS6H: 36-pin spring clamp block
Wire Size:
0.33–2.1 mm² (22–14 AWG) solid or stranded shielded copper wire, rated at 105°C (221°F) or greater, 1.2 mm insulation max
Torque: 0.5–0.6 Nm (4.4–5.3 lb-in) for 1756-TBCH
Wiring Options: Supports Removable Terminal Blocks (RTBs) or 1492 Interface Modules (IFMs) with pre-wired cables
Environmental Specifications:
Operating Temperature: 0°C to 60°C (32°F to 140°F)
Storage Temperature: -40°C to 85°C (-40°F to 185°F)
Relative Humidity: 5% to 95% (non-condensing)
Vibration: 2G @ 10–500 Hz
Shock: 15G (operating), 30G (non-operating)
Enclosure Type: Open-type
Emissions: CISPR 11, Group 1, Class A
ESD Immunity: IEC 61000-4-2 (6 kV contact, 15 kV air)
Radiated RF Immunity: IEC 61000-4-3 (10 V/m, 30 MHz to 2000 MHz)
Temperature Codes: T4 (North America, IEC, ATEX)
Other:
Conversion Method: R-Ladder DAC for outputs, Delta-Sigma ADC for inputs, monotonicity with no missing codes
Data Formats: IEEE 32-bit floating point, Integer (left-justified, 2’s complement)
Indicators: Bi-colored LED for module status (red/green), CAL status indicator
Certifications: UL, CSA, CE, C-TICK, ATEX, FM, KC, IECEx, ABS
Functions
High-Speed Analog I/O:
Provides 4 high-speed, sub-millisecond differential inputs for precise measurement of voltage (±10V, 0–10V, 0–5V) or current (0–20 mA) signals.
Offers 2 high-speed voltage (±10V) or current (0–20 mA) outputs for rapid control of analog devices like valves or VFDs.
Synchronized Sampling:
Supports sub-millisecond channel scans and synchronized sampling across multiple modules, ideal for time-critical applications requiring coordinated data acquisition.
Protection Features:
Overvoltage Protection: 30V DC (inputs, voltage mode), 8V AC/DC (inputs, current mode), 24V DC (outputs).
Short-Circuit Protection: Electronically limits output current to 21 mA or less.
Open-Circuit Detection: Detects open circuits in current mode for inputs (within 1 second) and outputs (>0.1 mA).
Diagnostics and Alarming:
Features real-time channel sampling and onboard data alarming for immediate fault detection (e.g., over/under range, open circuit).
Includes a display for module health and operation state (e.g., calibration mode).
Flexible Data Handling:
Supports IEEE 32-bit floating point and Integer data formats for compatibility with various control algorithms.
Uses R-Ladder DAC for outputs and Delta-Sigma ADC for inputs, ensuring accurate and monotonic signal conversion.
System Integration:
Integrates with ControlLogix controllers via ControlNet, EtherNet/IP, or DeviceNet networks.
Supports local or distributed I/O configurations, compatible with Studio 5000 Logix Designer for configuration and diagnostics.
Modular Design:
Supports Removal and Insertion Under Power (RIUP) with removable terminal blocks (1756-TBCH, 1756-TBS6H), simplifying maintenance and reducing downtime.
Compatible with 1492 Interface Modules (IFMs) for pre-wired cabling options.
Application Scenarios
High-Speed Process Control:
Used in applications requiring rapid response, such as controlling high-speed valves, actuators, or VFDs in chemical processing, oil and gas, or water treatment.
Ideal for precise modulation of flow, pressure, or temperature in time-critical processes.
Manufacturing Automation:
Drives VFDs or servo motors in production lines for automotive manufacturing, packaging, or material handling, where sub-millisecond response ensures accurate control.
Supports high-speed data acquisition for real-time monitoring of sensors in robotic systems.
Motion Control:Interfaces with motion control devices requiring fast analog inputs/outputs, such as position or velocity feedback systems in CNC machines or conveyor systems.
Distributed Control Systems:Deployed in distributed I/O setups via ControlNet or EtherNet/IP, enabling centralized control of remote analog devices in large-scale facilities like power plants or refineries.
Signal Re-Transmission:Re-transmits analog signals (e.g., 4–20 mA) to interface with external indicators, recorders, or SCADA systems, supporting process monitoring and data logging.
Legacy System Upgrades:Integrates with PLC-5 systems (via adapters) or serves as a key component in modernizing to ControlLogix platforms, replacing older 1771 series modules (e.g., 1771-NBSC) for enhanced speed and resolution.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies