1747-DCM Allen Bradley Rockwell SLC 500 Direct Communication Module
1747-DCM is a Direct Communication Module for the SLC 500 systems.
HS CODE : 8538909200
Product No :
1747-DCM 1747DCMManufacture :
Allen BradleySize (cm) :
13 * 15 * 7.5Weight (kg) :
0.168Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
Communication ModuleProduct parameters
Model: 1747-DCM (Series A)
Type: Direct Communication Module (RIO Adapter)
Communication port: 1 RIO link port (6-pin Phoenix connector)
Backplane current: 360 mA @ 5 VDC 0 mA @ 24 VDC
Power consumption: Maximum 1.8W
Heat dissipation: Maximum 1.8W (6.14BTU /hr)
Supported controllers: SLC 500 fixed and modular controllers
Supported modules: Compatible with all SLC 500 I/O modules
Connection cable: Belden 9463 or equivalent cable
Protection grade: IP20 (Open Type)
Operating temperature: 0... +60°C (+32… +140°F)
Storage temperature: -40... +85°C (-40… +185°F)
Relative humidity: 5... 95% (No condensation)
Vibration: 2.5g @ 5-2000 Hz
Operating impact: 30 g
Certifications: UL, CSA, CE, ATEX, IECEx, Korean KC, RCM, NEMA ICS 2-230
Installation method: Rack installation, installed in any slot of the SLC 500 rack.
Rack compatibility: Compatible with 1746 series racks.
Wiring: 6-pin Phoenix connector, using Belden 9463 cable.
Function
Remote I/O communication: Connect the SLC 500 controller to the PLC-5 or other RIO scanners via the RIO link to achieve distributed data exchange.
Flexible baud rate: Supports baud rates of 57.6K, 115.2K and 230.4K, with a maximum communication distance of 3048 meters, suitable for large factory networks.
Extended node capability: Supports up to 32 adapters to enhance network scalability.
DIP switch configuration: It is equipped with two sets of 8-bit DIP switches for setting the logic rack number, I/O group number and rack size.
Status indication: Provide FAULT and COMM LED indicator lights for fault diagnosis and communication status monitoring:
FAULT (red) : Module failure or configuration error
COMM (green) : Normal communication
No user programming required: Configure the address and mode through the DIP switch without additional programming.
Compatibility: Supports SLC 500 fixed and modular controllers, and is compatible with all SLC 500 I/O modules.
Application scenarios
Distributed Control System (DCS): It is used in the chemical, water treatment, and oil and gas industries, and realizes remote I/O data exchange through the RIO network.
Automated production line: Connecting I/O devices such as sensors and actuators, it is suitable for CNC machine tools, assembly lines, and packaging equipment.
Remote monitoring: Remote programming and control are achieved through the SCADA system, making it suitable for factory automation or public utilities.
Logistics and warehousing: Control distributed I/O devices such as conveyor belts and sorting systems.
Energy management: Remote data collection for power or public utility systems.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies