INNIS21 is the Network Interface Slave Module in the ABB Bailey INFI 90 system and belongs to the key interface component of industrial automation and distributed control systems (DCS).
HS CODE : 8538909200
Product No :
INNIS21 ABBManufacture :
ABBSize (cm) :
35.8*27.1*7.3Weight (kg) :
2Origin :
SwedenWarranty :
12 MonthLead Time :
Ready StockDescription :
NETWORK INTERFACE SLAVE MODULEProduct parameters
Manufacturer: ABB Bailey
Model: INNIS21
Processor: Integrated microprocessor, supporting INFI-NET slave node operations
Memory: Supports ROM and SRAM configurations, used for data buffering and protocol processing
Communication interface: INFI-NET network interface, supporting communication from nodes
Supported protocols: Ethernet/IP, Modbus TCP, PROFINET IO
Connector: Standard INFI 90 bus interface
Redundancy support: Compatible with primary and backup redundancy configurations, providing high availability
Power supply requirement: + 5VDC, maximum power consumption approximately 10W
Compatibility: Fully compatible with INFI 90 OPEN system and Symphony Harmony
Others: LED status indication, supporting diagnosis and firmware upgrade; Tariff Number: 85176200 Certificates: CE, FCC
Size module form: Standard printed circuit board (PCB) module
Function
Network interface: As a slave module, it provides a physical connection between the network and the slave device, achieving data routing and protocol conversion
Communication Management: Supports high-speed data transmission, reliable connection and advanced encryption to ensure real-time message delivery
Diagnostic capability: Built-in diagnostic tools for monitoring network status, fault detection and maintenance simplification
Configuration flexibility: Supports flexible configuration options to adapt to different network topologies
Data processing: Process control data, alarms and logs, and support system expansion
Enhanced reliability: Robust design, providing scalability and industrial-grade durability
Application scenarios
Distributed control system: INFI 90 DCS for the petrochemical, power and pharmaceutical industries, achieving network communication and automatic control
Factory automation: In manufacturing plants and process control systems, it provides integration from nodes and data exchange
Critical infrastructure: Applicable to power plants, oil and gas refineries, and water treatment facilities, ensuring continuous operation through redundancy support
System Expansion: Integrated into the Symphony Plus environment for network upgrades, trend analysis and remote monitoring, suitable for medium and large-scale industrial projects.
Advantage Products:
| DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
| KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
| GE FANUC | PACSystems RX3i,90-30,90-70 | ||
| SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
| BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
| HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
| ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
| WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 | ||
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!

| Conditions | Original Brand New | 
| Approximate Lead Time | 3-5 days | 
| Warranty | One Year | 
| Online Service | 24 / 7 | 
| Express Company | DHL / FedEx / UPS / TNT etc. | 
| MOQ | 1 Piece | 
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
 
						 
			Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies