HUAWEI CR5D00E8NB7S INTEGRATED LINE PROCESSING BOARD CM
Product No :
HUAWEI CR5D00E8NB7SManufacture :
HUAWEISize (cm) :
39.9*53.5*4Weight (kg) :
10.6Origin :
CHINAWarranty :
12 MonthLead Time :
Ready DRIVEDescription :
INTEGRATED LINE PROCESSING BOARD CMComponent code :03050JGK
Model :CR5D00E8NB7S
Single board category: Fixed board
Silk screen printing
LPUI-1T2A-CM
16x50/8x100GBase-QSFP28
Typical power consumption [W]: 464.27W
Typical heat dissipation value [BTU/hour]:1506.29 BTU/hour
Long-term operating environment temperature [°C]:0°C to 45°C
Short-term operating environment temperature [°C]:-5°C to +55°C
Basic function: Supports 800G line-speed forwarding.
Reliability and availability: Supports hot plugging.
Restrictions and Instructions:
Even ports (0/0, 0/2, 0/4, 0/6, 1/0, 1/2, 1/4, 1/6) can operate in 4*10GE hash /40GE/50GE/100GE mode, with a default of 50GE. They can be switched to 50GE/100GE mode through the command line port-speed. Switch to the 40GE/4*10GE hash mode through the command line port split. Odd-numbered ports (0/1, 0/3, 0/5, 0/7, 1/1, 1/3, 1/5, 1/7) can only operate in the 50GE mode.
2. If an even port operates in 4*10GE hash /40GE/100GE mode, the adjacent next odd 50GE port will not work. For example, if port 0 operates in 4*10GE hash /40GE/100GE mode, then port 1 cannot work. If port 0 operates in 50GE mode, Port 1 can also operate in 50GE mode. By analogy, ports 2 and 3, 4 and 5, and 6 and 7 have similar constraints.
3. Four 10GE ports scattered from the same QSFP+ port must operate simultaneously in 10GE WAN or 10GE LAN mode and do not support the coexistence of 10GE WAN and 10GE LAN. The 10GE WAN interface only supports the master clock mode. The default transmission rate of this single-board interface is 50G. When the transmission rate of the supported optical module interface used in conjunction does not match the default rate, for example, when using a 40G optical module, the port split enables the hash interface function to be executed.
4. In different modes of 100GE/50GE/40GE/10GE, optical modules of different rates need to be used in combination.
When this single board is used in conjunction with the 02312NCX optical module or the 02312MLF optical module, the long-term operating temperature of the optical module is 0°C to 45°C.
6. Ports 0/0-0/7 and 1/0-1/7 support FlexE features.
7, on the front panel port according to the following groups: 0/0, 0/1} {, {.two survivors, 0/3}, {} 0/4, 0/5, 0/6, 0/7} {, {} 1/0, 1/1, 1/2, 1/3 {}, {1/4, 1/5}, {} 1/6, 1/7
FlexE ports of the same rate within the same group can be bundled through configuration. For example, every two 50G ports can be bound into a group through FlexE, and the maximum rate of FlexE service ports within this group can be configured to 100Gbps.
Whether hashing is supported: Yes
To enable the hash interface, the command "port split" needs to be executed to complete the hash configuration.
Whether port rate adaptation is supported: Yes
To enable the adaptive mode, the command "switch-mode manual" needs to be executed to complete the adaptive configuration.
Does it support FlexE? Yes
(0,1) Physical ports can join the same Group, and the range of port-id is 8-15 and 1000-3000. The number of FlexE Clients supported for creation is 8.
(2,3) Physical ports can join the same Group, and the range of port-id is 16-23 and 1000-3000. Support the creation of 8 FlexE Clients.
(4,5) Physical ports can join the same Group, and the port-id range is 24-31, 1000-3000. The number of FlexE Clients supported for creation is 8.
(6,7) The physical ports can join the same Group, and the port-id range is 32-39 and 1000-3000. The number of FlexE Clients supported for creation is 8.
Does it support MACsec? Yes
Does it support the use of RTU? Yes
The default controlled port is 100M. If you want to use the bandwidth of other ports, you need to load the RTU.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Something You Might Need:
HUAWEI | DANFOSS | OMRON | SCHNEIDER |
CR5DLPUFF37U | 060G1110 | R88M-WP40030H-B | BMXCPS4002 |
CR5DLPUFF396 | 060G1111 | R88M-WP20030T-B | BMXDAI0805 |
CR5DLPUFF398 | 060G1112 | R88M-K90010H-S2 | BMXDAI0814 |
CR5DLPUFF377 | 060G1113 | R88M-G1K530H-BS2-Z | BMXDAI1602 |
CR5DLPUFF37Q | 060G1121 | R88M-G1K530H-BS2 |
BMXDAI1603 |
CR5DLPUFF37V | 060G1122 | R88D-KN08H-ECT | BMXDAI1604 |
CR5DLPUFF399 | 060G1123 | R88D-KN10H-ECT-Z | BMXDAI1614 |
CR5DLPUFF39A | 060G1124 | R88M-WP75030T-S2 | BMXDAI16142 |
CR5DLPUFF073 | 060G1125 | R88D-KN20F-ECT-Z | BMXDAI1615 |
CR5DLPUFF07H | 060G1128 | R88M-1M75030H | BMXDAO1605 |
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies