6ES7414-5HM06-0AB0 Siemens SIMATIC S7-400H CPU 414-5H Central Processing Unit
6ES7414-5HM06-0AB0 is a CPU module for the SIMATIC S7-400H and S7-400F/FH systems.
HS CODE : 8538909200
Product No :
6ES7414-5HM06-0AB0 6ES74145HM060AB0Manufacture :
SiemensSize (cm) :
30 * 23 * 6.3Weight (kg) :
1.32Origin :
GermanyWarranty :
12 MonthLead Time :
Ready StockDescription :
Processor UnitProduct parameters
Model: 6ES7414-5HM06-0AB0
Product Type: SIMATIC S7-400H Series Central Processing Unit (CPU 414-5H)
Working memory: 4 MB (2 MB code, 2 MB data)
Interface:
First interface: MPI/DP, 12 Mbit/s (RS485/Profibus)
Second interface: PROFIBUS DP
Third interface: PROFINET (PN)
Fourth/Fifth interface: 2 for synchronization modules (supporting high availability systems)
Firmware version: V6.0.1 / V6.0.2 / V6.0.3 (loadable)
Programming software: STEP7 V5.5 or higher version, including hardware updates
Power supply:
Power supply: Through the system power supply (such as 6ES7407-0KA02-0AA0)
Backplane bus current: 5V DC, typically 1.6A
Processing time:
Bit operation: approximately 31.25 ns
Word operation: approximately 31.25 ns
Fixed-point operation: approximately 31.25 ns
Floating-point operation: approximately 93.75 ns
Memory
Data blocks (DB) : Up to 6,000, with a maximum of 64 KB per block
Function blocks (FB/FC) : Up to 3000, with a maximum of 64 KB per block
Process image: 8 KB each for input and output
Operating temperature: 0°C to 60°C
Certification: CE, in compliance with EN 954-1 Category 4 and RoHS
Status: Current product, suitable for S7-400H and S7-400F/FH systems
Function
High availability and fault safety: Specifically designed for S7-400H redundant systems and S7-400F/FH fault safety systems, it supports hot backup and fault switching to ensure zero downtime and meet high availability requirements.
High-performance processing: 4 MB memory, capable of rapidly handling complex logic and data-intensive tasks, suitable for mid-to-high-end automation control.
Multi-interface communication
The MPI/DP interface supports multi-point communication and distributed I/O control, with a rate as high as 12 Mbit/s.
The PROFIBUS DP interface connects distributed devices, such as sensors, actuators or Hmis.
The PROFINET interface supports real-time Ethernet communication, enhancing network integration capabilities.
The two synchronization module interfaces support the dual-CPU synchronous operation of the S7-400H system.
Diagnostic function: Real-time monitoring of system status through LED indications (INTF, EXTF, BUS1F, BUS2F, FRCE, RUN, STOP) simplifies fault detection.
Flexible expansion: Supports 1 central rack and 21 expansion units, with a maximum of 65,536 digital channels and 4,096 analog channels, suitable for large-scale systems.
Programming support: Compatible with the STEP7 programming environment, supports multiple programming languages (such as LAD, FBD, STL), and supports CiR (Configuration in Motion) to reduce downtime.
Application scenarios
Process Automation
Chemical engineering and pharmaceuticals: Used for data-intensive tasks such as formulation management, process monitoring, and batch processing, ensuring high precision and stability.
Oil and gas industry: Manage oil refining or natural gas processing systems and ensure continuous operation through redundant design.
Manufacturing industry
Automobile manufacturing: Control high-speed production lines (such as assembly lines, welding robots), provide rapid processing and deterministic response times, and shorten machine cycles.
Mechanical manufacturing: Used in CNC machine tools or packaging machinery to meet complex control requirements.
Energy industry
Power plant: Control key equipment such as turbines and generators to ensure high availability and fault safety.
Substation: Manages high-voltage distribution systems and supports redundant configuration to prevent power outages.
High availability scenarios: Used in high-cost downtime scenarios that require zero downtime (such as steel mills and mining), to prevent high restart costs or data loss caused by controller failures.
Distributed control: Through the PROFINET and PROFIBUS DP interfaces, it is suitable for remote monitoring and distributed I/O systems, such as large factories or infrastructure.
Advantage Products:
DANFOSS | VLT® AutomationDrive,Plus+1®,MCP | ||
KEYENCE | KV-800,KV-300,KP-3000,KP-7000,KJ,KV-Nano,HMI | ||
GE FANUC | PACSystems RX3i,90-30,90-70 | ||
SCHNEIDER | Modicon M340,Modicon M580,Modicon X80,Pioneer | ||
BENTLY NEVADA | 3500/94,3500/53,3500/22M,3500/42M,330180-90-00 | ||
HONEYWELL | Experion® PKS,ControlEdge™ ,HC900 | ||
ALLEN BRADLEY | CompactLogix,ControlLogix, MicroLogix,Flex I/O | ||
WESTINGHOUSE | Westinghouse Modbus,Westinghouse 9080,Westinghouse 8000,Westinghouse 1000 |
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L(Sales Manager)
Tina(Sales Specialist)
Ricardo(Sales Specialist)
Tel:+86 18359251915
Doris(Sales Specialist)
Tel:+86 13599531915
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies